Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Durability and Fatigue Behavior of CIP Concrete Connections for Accelerated Bridge Construction
Details

Durability and Fatigue Behavior of CIP Concrete Connections for Accelerated Bridge Construction

Date Issued
December 1, 2010
Author(s)
Zhu, Peng
Advisor(s)
Zhongguo John Ma
Additional Advisor(s)
Edwin G. Burdette
Baoshan Huang
John Stanley Rabun
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/30430
Abstract

Continuous longitudinal and transverse U-bar joint connections between flanges of the decked bulb-Ts (DBTs) or between precast panels for accelerated bridge construction are investigated. The procedure for selecting durable closure pour (CP) materials for the connections is discussed firstly. The accelerated construction is quantified as two categories: overnight cure and 7-day cure of CP materials. Candidate materials are selected first based on literature review as well as tests of compressive strength and flow and workability. Then, performance criteria for selecting durable CP materials for both categories are developed based on durability tests of selected candidate materials. These durability tests include freezing-and-thawing durability, shrinkage, bond, and permeability tests. To investigate the longitudinal U-bar joint details, four pairs of full-scale slabs connected by a U-bar detail with one of the selected CP materials, overnight cure and 7-day cure, were tested. The loading demand necessary in the slab testing is determined based on the maximum forces in the longitudinal joint from an analytical parametric study. Static and fatigue tests under four-point flexural loading and three-point flexural-shear loading were conducted. Test results were evaluated based on flexural capacity, curvature behavior, cracking, deflection and steel strain. The transverse U-bar joint details are investigated to provide negative moment continuity in the multi-span bridges. Four full-scale specimens connected by a U-bar detail with one of the selected CP materials, overnight cure and 7-day cure, were tested. Static and fatigue tests under tension loading were conducted. The loading demand necessary in the beam testing is determined based on the maximum forces in the transverse joint from an analytical study. Test results were evaluated based on tension capacity, cracking, displacement and steel strain. Based on the test results, the developed longitudinal and transverse U-bar joint details are viable connection systems.

Subjects

Closure pour material...

Durability

Performance criteria

Fatigue

Longitudinal joint

Transverse joint

Disciplines
Structural Engineering
Degree
Doctor of Philosophy
Major
Civil Engineering
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

ZhuPengDec2010.docx

Size

5.66 MB

Format

Microsoft Word XML

Checksum (MD5)

86e963103010f039ef8b532b04097c60

Thumbnail Image
Name

zhu.pdf

Size

2.81 MB

Format

Adobe PDF

Checksum (MD5)

98b1be9f29e4d2132ccdc6a8bc0d2446


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science