Data Center Power System Emulation and GaN-Based High-Efficiency Rectifier with Reactive Power Regulation

Date Issued
May 1, 2022
Author(s)
Sun, Jingjing  
Advisor(s)
Leon M. Tolbert
Additional Advisor(s)
Leon M. Tolbert
Daniel J. Costinett
Helen Cui
Xueping Li
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/28497
Abstract

Data centers are indispensable for today's computing and networking society, which has a considerable power consumption and significant impact on power system. Meanwhile, the average energy usage efficiency of data centers is still not high, leading to significant power loss and system cost.


In this dissertation, effective methods are proposed to investigate the data center load characteristics, improve data center power usage efficiency, and reduce the system cost.

First, a dynamic power model of a typical data center ac power system is proposed, which is complete and able to predict the data center's dynamic performance. Also, a converter-based data center power emulator serving as an all-in-one load is developed. The power emulator has been verified experimentally in a regional network in the HTB. Dynamic performances during voltage sag events and server load variations are emulated and discussed.

Then, a gallium nitride (GaN) based critical conduction mode (CRM) totem-pole power factor correction (PFC) rectifier is designed as the single-phase front-end rectifier to improve the data center power distribution efficiency. Zero voltage switching (ZVS) modulation with ZVS time margin is developed, and a digital variable ON-time control is employed. A hardware prototype of the PFC rectifier is built and demonstrated with high efficiency. To achieve low input current total harmonic distortion (iTHD), current distortion mechanisms are analyzed, and effective solutions for mitigating current distortion are proposed and validated with experiments.

The idea of providing reactive power compensation with the rack-level GaN-based front-end rectifiers is proposed for data centers to reduce data center's power loss and system cost. Full-range ZVS modulation is extended into non-unity PF condition and a GaN-based T-type totem-pole rectifier with reactive power control is proposed. A hardware prototype of the proposed rectifier is built and demonstrated experimentally with high power efficiency and flexible reactive power regulation. Experimental emulation of the whole data center system also validates the capability of reactive power compensation by the front-end rectifiers, which can also generate or consume more reactive power to achieve flexible PF regulation and help support the power system.

Subjects

data center

GaN

emulation

rectifier

soft switching

modeling

control

Disciplines
Electrical and Electronics
Power and Energy
Degree
Doctor of Philosophy
Major
Electrical Engineering
File(s)
Thumbnail Image
Name

Jingjing_Sun_dissertation_final_03292022.pdf

Size

24.08 MB

Format

Adobe PDF

Checksum (MD5)

a8b82e66e24ffa24f1b96e8364e8032f


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science