Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. The analysis of nonfluorescent compounds by electron impact-and laser photolysis-fragmentation fluorescence spectrometry
Details

The analysis of nonfluorescent compounds by electron impact-and laser photolysis-fragmentation fluorescence spectrometry

Date Issued
December 1, 1988
Author(s)
Jinkins, Jane Katherine Gates
Advisor(s)
E. L. Wehry
Additional Advisor(s)
J. Q. Chambers
R. N. Compton
R. Pagni
D. W. Weeter
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/20157
Abstract

The development of alternative, fluorescence-based analytical techniques is being driven by two important properties of conventional fluorometric techniques; one, the characteristically low limits of detection obtainable for intensely fluorescent compounds and, two, the relatively small number of compounds possessing high quantum yields for fluorescence.


Small molecules, e.g., diatomics, triatomics, and atoms, are known to be intensely luminescent. Fragmentation Fluorescence Spectrometry (FFS) is a technique that takes advantage of this property and the fact that virtually any organic or organometallic compound can be broken into small molecular fragments. In the work presented in this dissertation, fragmentation of gas-phase molecules is accomplished through either the absorption of photons by laser photolysis (LP) or electron-impact bombardment (El). The fluorescence is measured directly and related to the original amount of the parent compound.

In the following document, quantitative analyses (limits of detection, linear dynamic range, and precision) were carried out on a number of individual compounds by both El- and LP-FFS. The detection limits of ammonia by El- and LP-FFS were 20 pmol and 3.4 pmol, respectively. The compounds methylamine and acetonitrile were also analyzed using both techniques, with detection limits by El of 0.3 nmol and 0.1 nmol, respectively, and by LP, 15 pmol, for methylamine. Acetonitrile did not produce fluorescent fragments under these IV V conditions of laser photolysis. Linear behavior was typical (2-3 decades) with the exception of ammonia in LP-FFS. Measurements made by EI-FFS are more reproducible than those of LP-FFS. Analytical precision as expressed by percent relative standard deviation was typically <1.5% for El- and -6% for LP-FFS.

The analysis of a series of aliphatic amines by LP-FFS indicated that detection limits do not dramatically increase for amines of higher molecular weights.

Studies of the use of a second laser with LP-FFS in a "photolysis-probe" arrangement to excite additional fluorescence from molecular fragments are described. No enhancement of fragment fluorescence was observed under the experimental conditions of this study.

Degree
Doctor of Philosophy
Major
Chemistry
File(s)
Thumbnail Image
Name

Thesis88b.J555.pdf

Size

4.86 MB

Format

Unknown

Checksum (MD5)

be321ef1bb8056e66a1577d1f4b0ab46


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science