  5. Characterization of a sampling tube used in a chemical filterpack sampler
Details

Characterization of a sampling tube used in a chemical filterpack sampler

Date Issued
May 1, 1991
Author(s)
Struder, Ray
Advisor(s)
Wayne T. Davis
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/33965
Abstract

A 100 cm long teflon sampling tube that is used in the National Oceanographic and Atmospheric Administration's chemical filterpack samplers was evaluated as to its effectiveness as a gravity settler. The evaluation found the tube to have a large variation of collection efficiency with time which is not anticipated in gravitational theory. The tube initially had large collection efficiencies before declining to theoretically predicted values. The tube was evaluated under numerous conditions and the following conclusions were determined. The high initial efficiencies are due to electrostatic forces and the tube's ultimate approximate efficiency for particles 2 to 7 microns in diameter is 3 to 6%, respectively. The tube's efficiency can be increased to over 50% by coiling it into a cyclonic configuration and applying a coating of silicone grease.

Degree
Master of Science
Major
Environmental Engineering
File(s)
Thumbnail Image
Name

Thesis91S878.pdf

Size

2.11 MB

Format

Unknown

Checksum (MD5)

55faa26744f50aebf31de67d5a8140b9


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science