Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Low-Voltage Bulk-Driven Amplifier Design and Its Application in Implantable Biomedical Sensors
Details

Low-Voltage Bulk-Driven Amplifier Design and Its Application in Implantable Biomedical Sensors

Date Issued
April 1, 2012
Author(s)
Zuo, Liang
Advisor(s)
Syed Islam
Additional Advisor(s)
Jeremy Holleman
Benjamin J. Blalock
Laurence F. Miller
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/22228
Abstract

The powering unit usually represents a significant component of the implantable biomedical sensor system since the integrated circuits (ICs) inside for monitoring different physiological functions consume a great amount of power. One method to reduce the volume of the powering unit is to minimize the power supply voltage of the entire system. On the other hand, with the development of the deep sub-micron CMOS technologies, the minimum channel length for a single transistor has been scaled down aggressively which facilitates the reduction of the chip area as well. Unfortunately, as an inevitable part of analytic systems, analog circuits such as the potentiostat are not amenable to either low-voltage operations or short channel transistor scheme. To date, several proposed low-voltage design techniques have not been adopted by mainstream analog circuits for reasons such as insufficient transconductance, limited dynamic range, etc. Operational amplifiers (OpAmps) are the most fundamental circuit blocks among all analog circuits. They are also employed extensively inside the implantable biosensor systems. This work first aims to develop a general purpose high performance low-voltage low-power OpAmp. The proposed OpAmp adopts the bulk-driven low-voltage design technique. An innovative low-voltage bulk-driven amplifier with enhanced effective transconductance is developed in an n-well digital CMOS process operating under 1-V power supply. The proposed circuit employs auxiliary bulk-driven input differential pairs to achieve the input transconductance comparable with the traditional gate-driven amplifiers, without consuming a large amount of current. The prototype measurement results show significant improvements in the open loop gain (AO) and the unity-gain bandwidth (UGBW) compared to other works. A 1-V potentiostat circuit for an implantable electrochemical sensor is then proposed by employing this bulk-driven amplifier. To the best of the author’s knowledge, this circuit represents the first reported low-voltage potentiostat system. This 1-V potentiostat possesses high linearity which is comparable or even better than the conventional potentiostat designs thanks to this transconductance enhanced bulk-driven amplifier. The current consumption of the overall potentiostat is maintained around 22 microampere. The area for the core layout of the integrated circuit chip is 0.13 mm2 for a 0.35 micrometer process.

Subjects

Low voltage

Low power

Biomedical

Disciplines
VLSI and Circuits, Embedded and Hardware Systems
Degree
Doctor of Philosophy
Major
Electrical Engineering
Embargo Date
January 1, 2012
File(s)
Thumbnail Image
Name

PhD_dissertation_LiangZuo_Apr19_final.pdf

Size

5.46 MB

Format

Adobe PDF

Checksum (MD5)

ebd916837a6d7d18cb879df035f7a473

Thumbnail Image
Name

PhD_dissertation_LiangZuo_Apr2nd_draft.docx

Size

23.3 MB

Format

Microsoft Word XML

Checksum (MD5)

023fa6ebbe70307183d97c83c4e4226b


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science