Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Development of Ultrasensitive Analytical Techniques to Detect Trace Elements
Details

Development of Ultrasensitive Analytical Techniques to Detect Trace Elements

Date Issued
December 15, 2019
Author(s)
Romero Romero, Elisa
Advisor(s)
Alfredo Galindo-Uribarri Dr.
Additional Advisor(s)
Adriana Moreo
Kenneth F. Read Jr
Lawrence W. Townsend
Soren P. Sorensen
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/26969
Abstract

In this thesis, two methods for ultra-trace analysis were investigated: the negative-ion based Accelerator Mass Spectrometry (AMS) and positive-ion based Resonant Ionization Mass Spectrometry (RIMS). The detection, monitoring and quantification of ultra-low levels of actinides is of considerable importance and represents a challenge in many fields of modern science: neutrino physics, dark matter searches, nuclear astrophysics, environmental science, etc. These fields demand more sensitive and more efficient techniques and are pushing the limits of conventional techniques for ultra-trace analysis. Employing the 14 MV tandem accelerator of the Australian National University, we demonstrated an AMS method capable of detecting ultra-low traces of Th and U from ultrapure Cu made underground for the Majorana Demonstrator. We made significant advancements on the actinide detection efficiency and sensitivity with the laser-based technique RIMS. We demonstrated that RIMS is a powerful analytical technique for actinides since it does not require large amount of material, has high selectivity, high efficiency and high sensitivity. Several three-step ionization schemes were studied and numerous high-lying and autoionizing levels were observed for Pu, Th, and U. We obtained efficiencies up to 51% for Pu, 32% for Th and 9% for U. These efficiencies represent the largest efficiencies reported for actinides and surpass significantly the efficiencies obtained in AMS for actinides which are between 0.1% to 1%. We performed sensitivity studies with a setup consisting of a Resonant Ionization Laser Ion Source (RILIS), a mass spectrometer based on the Holifield Radioactive Ion Beam Facility radioactive injector IRIS2 and a single ion counter. We obtained a detection limit of 103 atoms for 240Pu which is 1-2 orders of magnitude below previously reported. Atomic spectroscopic studies for Pu were done revealing four Rydberg series in the energetically high-lying region in the atomic spectrum. The first ionization potential (IP) of Pu was precisely determined as 48605.748 (95)stat(49)sys cm−1 using two methods. This value is a factor of three more precise than the one reported in the NIST database and constitutes a benchmark for modern relativistic atomic theories.

Subjects

Resonant Ionization M...

Accelerator Mass Spec...

Actinides

Ultra-sensitive techn...

Neutrino experiments

Ion source

Degree
Doctor of Philosophy
Major
Physics
Embargo Date
December 15, 2020
File(s)
Thumbnail Image
Name

utk.ir.td_12627.pdf

Size

106.02 MB

Format

Adobe PDF

Checksum (MD5)

b64884683ce6138cd7302903b9c07d6b


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science