Quantitative evaluation of the effects of transient heat tranfer on axial flow compressor stability

Date Issued
December 1, 1984
Author(s)
Fowley, Mark D.
Advisor(s)
Roger A. Crawford
Additional Advisor(s)
Roy Schulz
John Caruthers
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/36287
Abstract

The purpose of this investigation is to study the effects of transient heat transfer on the stability of axial flow compressors. During speed transients the state of the compressor can be considered non-adiabatic. This is due to heat transfer between the compressor metal parts and the air flow. For instance, during a deceleration, heat is transferred from the hot metal to the cooler air. This phenomenon is detrimental to the stability margin of the compressor. The density changes of the air and boundary layer reactions during heat transfer reduce the margin of stability. When a deceleration is immediately followed by an acceleration the surge margin reduction becomes even worse. The response of a compressor during an acceleration can reduce the surge margin even further. Since the surge margin has already been diminished due to heat transfer, the possibility of the compressor becoming unstable is greater.


First, this investigation thoroughly researched the topic of the effects of heat transfer on compressor stability. Then using engine test data the thermal energy storage capacity for a typical engine and the heat transfer rate during a speed transient were quantified. The transient investigated was a "bodie" transient, which is a standard engine stability test for gas turbine engines. The "bodie" transient is a deceleration followed by an acceleration. Instabilities usually occur during the acceleration part of the transient. Only pre-stall conditions were analyzed, i.e., only the deceleration was investigated. The heat transfer rate was quantified for four sets of back to back data points that were run at similar operating conditions. One of the tests encountered a stall; the other did not. Through an analysis procedure, it was determined that the stalled test had a greater heat transfer rate than the unstalled test. This demonstrates the link between the occurrence of compressor instability and heat transfer during speed transients.

Degree
Master of Science
Major
Mechanical Engineering
File(s)
Thumbnail Image
Name

Thesis84F692.pdf

Size

1.64 MB

Format

Unknown

Checksum (MD5)

ccf0e3d6d7ec3702c2901004e2e1b45d


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science