Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Theoretical Modeling and Experimental Validation of In Vivo Mechanics for Subjects Having Variable Cervical Spine Conditions
Details

Theoretical Modeling and Experimental Validation of In Vivo Mechanics for Subjects Having Variable Cervical Spine Conditions

Date Issued
December 1, 2007
Author(s)
Liu, Fei
Advisor(s)
Richard D. Komistek
Additional Advisor(s)
Mohamed R. Mahfouz
William R. Hamel
Jack F. Wasserman
Ramon V. Leon
Joseph S. Cheng
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/25380
Abstract

The objective of this study was to use the state-of-art 3D-to-2D registration technologies including fluoroscopic, CT and MRI methods to analyze 2D and 3D in vivo kinematics of the whole cervical spine under variable conditions; and use inverse dynamic model based on Kane’s dynamics to predict their 2D and 3D in vivo interactive contact and muscular forces. Totally, forty patients (ten having normal cervical spines, ten having degenerative cervical spines, ten having anterior cervical decompression and fusion (ACDF), and ten having cervical artificial disc replacement (CADR)) were enrolled into 2D study and three patients (one having normal cervical spines, one having degenerative cervical spines, one having ACDF) were involved into 3D study. All of the patients had their symptoms, if any, at the C5-C6 level. Error analysis was performed on an entire cadaveric cervical spine. Two major mathematical models were derived using the principles governing Kane’s dynamics. At the adjacent levels, both 2D and 3D study showed the ACDF group had relatively larger kinematic and kinetic data compared to the normal group, the degenerative group had relatively smaller kinematic and kinetic data. At the same time, 2D study demonstrated that the CADR group had similar kinematic and kinetic data compared to the normal group. Cadaveric error analysis demonstrated that the 3D-to-2D registration method and the inverse dynamic method had high accuracy and can be used in the cervical spine field.

Disciplines
Biomedical Engineering and Bioengineering
Degree
Doctor of Philosophy
Major
Biomedical Engineering
Embargo Date
December 1, 2007
File(s)
Thumbnail Image
Name

LiuFei.pdf

Size

5.79 MB

Format

Adobe PDF

Checksum (MD5)

a15cc14970eaa1a75d4748addaf03426

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify