EFFECT OF MOISTURE ABSORPTION ON THE SINTER QUALITY OF CENTRAL SOLENOID (CS) COIL PACK

Date Issued
December 1, 2010
Author(s)
Mohammed, Zeshaan Sher  
Advisor(s)
Madhu S. Madhukar
Additional Advisor(s)
John D. Landes
J.A.M. Boulet
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/44711
Abstract

Fusion energy has been said to be the solution to all the world’s energy problems. The International Thermonuclear Experimental Reactor (ITER) is the flagship project to demonstrate the feasibility of fusion energy. The Central Solenoid (CS), an important component of the reactor, is needed to induce plasma current, initiate, ramp-up, ramp-down, and sustain plasma in a very controlled manner. In order to achieve this, the CS coil packs must be manufactured under controlled conditions. The CS conductor is an advanced cable-in-conduit Nb3Sn superconductor. The CS cable will be made in long continuous sections but with thousands of meter of cable needed, splices will have to be made in the field during construction of the ITER reactor. With the ends of the CS cable being exposed to the environment for an unspecified amount of time, concern has been expressed about the effect of the cable exposure on the quality of the splice. As a result an experimental program was devised to replicate and expedite the environmental damage the cable may see while in the field.


The CS cable samples were exposed to 100% humidity at 60, 80, and 100oC for periods ranging from one week to four weeks. Once the samples were soaked for a period of time they were then sintered as would be done in the field. After sintering the mechanical tests were done to determine the load required to push the sintered strands out of the copper sleeve. Initial results obtained with samples having the sleeve thickness of 1.25mm (0.05in) were inconclusive due to the presence of a fold in the copper sleeve formed during the compaction of the sleeve around the cable. To prevent the fold formation, another set of samples were prepared with thicker copper sleeve of 5mm (0.20in).

Results from these samples yielded data that was more conclusive and showed a possible correlation between aging temperature and sintering strength. The experimental data suggests that the thin oxide layer formed during the elevated temperature soak at 100% humidity may even be beneficial to the sinter quality.

Subjects

Copper

Sintering

Superconducting

Cable

ITER

Oxide

Disciplines
Applied Mechanics
Mechanics of Materials
Metallurgy
Other Engineering Science and Materials
Other Materials Science and Engineering
Other Mechanical Engineering
Degree
Master of Science
Major
Mechanical Engineering
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

Soak_Sinter_of_CS_Coil_Pack.docx

Size

70.63 MB

Format

Microsoft Word XML

Checksum (MD5)

ed091f207d0c40f79f979b3a4659066f

Thumbnail Image
Name

Soak_Sinter_of_CS_Coil_Pack.pdf

Size

20.34 MB

Format

Adobe PDF

Checksum (MD5)

127021a44a14ccafc399d230d09d8165


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science