Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Lifetime Estimation of IGBTs in a Grid-connected STATCOM
Details

Lifetime Estimation of IGBTs in a Grid-connected STATCOM

Date Issued
December 1, 2014
Author(s)
Gopi Reddy, Lakshmi Reddy  
Advisor(s)
Leon M. Tolbert
Additional Advisor(s)
Burak Ozpineci
Fei Wang
J. Wesley Hines
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/24220
Abstract

Lifetime estimation of power semiconductor devices, and IGBT devices in particular, used in the power electronics integrated with power systems has gained technical importance in recent times with increased scope of distributed generation, renewable energy systems and FACTS. Since most of the common failures (wire bond and solder fatigue) are caused by thermo-mechanical stresses, the methodology of lifetime estimation starts with temperature estimation, cycle counting based on rainflow algorithm, and finally degradation calculation based on linear accumulation model.


Different number of RC cells for each packaging layer in the module for the thermal model, including the influence of encapsulant is proposed for temperature estimation of IGBTs in power modules. A modified rainflow algorithm with faster execution time and time dependent temperature calculation is introduced for cycle counting. Finally, the lifetime of the IGBT is estimated during STATCOM operation using real-time load profiles for power factor variation. For a power factor variation data for a building, the lifetime is estimated to be about 3 years. Similarly, a month long arc furnace load data is considered to compare the equivalent temperature based calculation to conventional tests. 4% more degradation is observed in the equivalent temperature based calculation than compared with conventional rainflow algorithm.

A simulation study on the operation parameter dependence on the stresses in a wire is considered to estimate lifetime from Finite Element Analysis (FEA) in COMSOL. Power cycling tests are conducted on two different modules (600 V, 50 A H-bridge module and a 1200 V, 150 A phase leg module) to validate the lifetime model for four months. The low power module was tested without any protection circuits and hence failed catastrophically. Wire melt-off or fusing failure was dominantly observed, following by dielectric based short circuit failure. The high power module was tested with protection circuits to prevent catastrophic damage for a maximum of 4 months. A maximum of 20% degradation in static characteristics, with decreased on state resistance was observed in the modules. The degradation is attributed to increased junction temperature as the thermal resistance increases owing to solder fatigue.

Subjects

lifetiem estimation

IGBTs

STATCOM

rainflow algorithm

compact thermal model...

Wirebond

failure s in semicond...

Disciplines
Power and Energy
Degree
Doctor of Philosophy
Major
Electrical Engineering
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

dissertation_lakshmi_final.pdf

Size

2.83 MB

Format

Adobe PDF

Checksum (MD5)

b72cc6de1ea5e47e917deb8fc46b8131


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science