Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. A Full Scale Camera Calibration Technique with Automatic Model Selection – Extension and Validation
Details

A Full Scale Camera Calibration Technique with Automatic Model Selection – Extension and Validation

Date Issued
August 1, 2007
Author(s)
Orekhov, Vitaliy Leonidovich
Advisor(s)
Mongi A. Abidi
Additional Advisor(s)
Besma Roui Abidi, Michael J. Roberts
Link to full text
http://etd.utk.edu/2007/OrekhovVitaliy.pdf
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/37723
Abstract

This thesis presents work on the testing and development of a complete camera calibration approach which can be applied to a wide range of cameras equipped with normal, wide-angle, fish-eye, or telephoto lenses. The full scale calibration approach estimates all of the intrinsic and extrinsic parameters. The calibration procedure is simple and does not require prior knowledge of any parameters. The method uses a simple planar calibration pattern. Closed-form estimates for the intrinsic and extrinsic parameters are computed followed by nonlinear optimization. Polynomial functions are used to describe the lens projection instead of the commonly used radial model. Statistical information criteria are used to automatically determine the complexity of the lens distortion model.


In the first stage experiments were performed to verify and compare the performance of the calibration method. Experiments were performed on a wide range of lenses. Synthetic data was used to simulate real data and validate the performance. Synthetic data was also used to validate the performance of the distortion model selection which uses Information Theoretic Criterion (AIC) to automatically select the complexity of the distortion model.

In the second stage work was done to develop an improved calibration procedure which addresses shortcomings of previously developed method. Experiments on the previous method revealed that the estimation of the principal point during calibration was erroneous for lenses with a large focal length. To address this issue the calibration method was modified to include additional methods to accurately estimate the principal point in the initial stages of the calibration procedure. The modified procedure can now be used to calibrate a wide spectrum of imaging systems including telephoto and verifocal lenses.

Survey of current work revealed a vast amount of research concentrating on calibrating only the distortion of the camera. In these methods researchers propose methods to calibrate only the distortion parameters and suggest using other popular methods to find the remaining camera parameters. Using this proposed methodology we apply distortion calibration to our methods to separate the estimation of distortion parameters. We show and compare the results with the original method on a wide range of imaging systems.

Disciplines
Electrical and Computer Engineering
Degree
Master of Science
Major
Electrical Engineering
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

OrekhovVitaliy.pdf

Size

2.2 MB

Format

Adobe PDF

Checksum (MD5)

c5891a70de09bd4c76f4da379ce92e9b

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify