Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. The Estimation of Caloric Expenditure Using Three Triaxial Accelerometers
Details

The Estimation of Caloric Expenditure Using Three Triaxial Accelerometers

Date Issued
December 1, 2012
Author(s)
Ceaser, Tyrone Gene
Advisor(s)
Dixie L, Thompson
Additional Advisor(s)
David R. Bassett Jr.
Eugene C. Fitzhugh
Paul C. Erwin
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/22442
Abstract

Accelerometer-based activity monitors are commonly used to measure physical activity energy expenditure (PAEE). Newly designed wrist and hip-worn triaxial accelerometers claim to accurately predict PAEE across a range of activities. Purpose: To determine if the Nike FuelBand (NFB), Fitbit (FB) and ActiGraph GT3X+ (AG) estimate PAEE in various activities. Methods: 21 healthy, college-aged adults wore a NFB on the right wrist, a FB on the left hip, and AG on the right hip, while performing 17 activities. AG data were analyzed using Freedson’s kcal regression equation. PAEE was measured using the Cosmed K4b2 (K4). Repeated measures ANOVAs were used to compare mean differences in PAEE (kcal/min). Paired sample t-tests with Bonferroni adjustments were used to locate significant differences. Results: For each device, the mean difference in PAEE was significantly different from the K4 (NFB, -0.45 + 2.8, FB, 0.48 + 2.27, AG, 0.64 + 2.59 kcal/min, p = 0.01). The NFB significantly overestimated most walking activities (e.g., regular walking; K4, 3.1 + 0.2 vs. NFB, 4.6 + 0.2 kcal/min) and activities with arm movements (e.g., sweeping; K4, 3.0 + 0.8 vs. NFB, 4.7 + 0.4 kcal/min, p < 0.05). The NFB trended towards overestimating sport activities (basketball; K4, 10.8 + 0.8 vs. NFB, 12.2 + 0.5 kcal/min) (racquetball; K4, 9.6 + 0.8 vs. NFB 11.1 + 0.5 kcal/min). The FB and the AG significantly overestimated walking (K4, 3.1 + 0.2; FB, 5.4 + 0.3, AG, 5.8 + 0.4 kcal/min, p = 0.01) and underestimated PAEE of most activities with arm movements (e.g., Air Dyne, K4 5.6 + 0.2; Fitbit, 0.3 + 0.2; AG, 0.2 + 0.1 kcal/min, p < 0.05) (racquetball, K4, 9.6 + 0.8 kcal/minute vs. FB, 7.4 + 0.6 kcal/minute, vs. AG, 6.5 + 0.4 kcal/minute, p < 0.05). Conclusion: The NFB overestimated PAEE during most activities with arm movements and tended to overestimate sport activities, while the AG and FB overestimated walking and underestimated activities with arm movements. Overall, the wrist-worn NFB had similar accuracy to the waist-worn triaxial accelerometers; however, none of the devices were able to estimate PAEE across a range of activities.

Subjects

physical activity

kilocalories

sensor

exercise

Disciplines
Sports Sciences
Degree
Doctor of Philosophy
Major
Kinesiology
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

0-Dissertation_Ch_1.docx

Size

40.12 KB

Format

Microsoft Word XML

Checksum (MD5)

9d8924e4c10e79e70343ffca00e420bf

Thumbnail Image
Name

Dissertation_Trace.docx

Size

607.25 KB

Format

Microsoft Word XML

Checksum (MD5)

96e5bd8f7392743560047422d0c9542c

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify