  6. Comparison of a human portable blood glucose monitor, a veterinary portable blood glucose monitor and an automated chemistry analyzer for measuring canine blood glucose concentration
Details

Comparison of a human portable blood glucose monitor, a veterinary portable blood glucose monitor and an automated chemistry analyzer for measuring canine blood glucose concentration

Source Publication
Journal of the American Veterinary Medical Association
Date Issued
January 1, 2009
Author(s)
Johnson, B M
Fry, Michael M  
Flatland, B
Kirk, C A
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/16414
Abstract

OBJECTIVE: To compare blood glucose concentrations measured with 2 portable blood glucose meters (PBGMs) validated for use in dogs (PBGM-D) and humans (PBGM-H) and an automated chemistry analyzer. DESIGN: Validation study. SAMPLE POPULATION: 92 samples of fresh whole blood and plasma from 83 dogs with various diseases. PROCEDURES: Each PBGM was used to measure whole blood glucose concentration, and the automated analyzer was used to measure plasma glucose concentration. Passing-Bablok linear regression and Bland-Altman plots were used to determine correlations and bias between the PBGMs and the automated analyzer. Calculated acceptability limits based on combined inherent instrument imprecision were used with Bland-Altman plots to determine agreement. Clinical relevance was assessed via error grid analysis. RESULTS: Although correlation between results of both PBGMs and the standard analyzer was > 0.90, disagreement was greater than could be explained by instrument imprecision alone. Mean difference between PBGM-H and chemistry-analyzer values was -15.8 mg/dL. Mean difference between PBGM-D and chemistry-analyzer values was 2.4 mg/dL. Linear regression analysis revealed proportional bias of PBGM-H (greater disagreement at higher glucose concentrations); no proportional bias was detected for PBGM-D. No constant bias was detected for either PBGM. Error grid analysis revealed all measurements from both PBGMs were within zones without an anticipated effect on clinical outcome. CONCLUSIONS AND CLINICAL RELEVANCE: Neither PBGM had exact agreement with the automated analyzer; however, the disagreement detected did not have serious clinical consequences. Our findings stressed the importance of using the same device for monitoring trends in dogs and using instrument-specific reference ranges.

Subjects

Glucometer

dog

method comparison

Disciplines
Veterinary Pathology and Pathobiology
File(s)
Thumbnail Image
Name

Comparisonofahuman.pdf

Size

384.95 KB

Format

Adobe PDF

Checksum (MD5)

283fe03d7dfc48db17d961c52b934bc4


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science