  5. The evaluation of thermally stimulated exoelectron emission detectors and electret ionization chambers for the purpose of measuring tritium on surfaces
Details

The evaluation of thermally stimulated exoelectron emission detectors and electret ionization chambers for the purpose of measuring tritium on surfaces

Date Issued
December 1, 1995
Author(s)
Brock, Jeffrey L.
Advisor(s)
Laurence Miller
Additional Advisor(s)
Peter Groer
James Turner
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/32312
Abstract

Currently, there are two accepted means of characterizing tritium surface contamination. Gas flow proportional counters meastire fixed and removable tritium and are difficult to operate in confined spaces. Removable tritium is measured with smears which are counted on a liquid scintillation system. The focus of this research is the evaluation of two types of small, solid state detectors for in situ measurements of total tritium contamination (fixed and removable). One type of detector is the Thermally Stimulated Exoelectron Emission (TSEE) detector. The other type is the Electret Ionization Chamber (EIC). Both types of detectors were studied for linearity and reproducibility using a solid, 100 cm2 tritium source (NIST traceable). Three variations of TSEE detectors were evaluated: Thin Film BeO, Ceramic BeO (Thermalox 995), and Carbon-doped Anion Deficient Al2O3. Only Thin Film BeO responded in a linear and reproducible fashion which had efficiencies (ratio of exoelectrons to incident beta particles) between 0.22 and 0.65 for one hour exposures. EICs also demonstrated a linear and reproducible response (2.55 V/hr of exposure). It was determined that an EIC response of 1 V/hr corresponds to an activity of approximately 79,000 dpm/100 cm2. Strong correlations existed in the laboratory environment between both detector types and the stated surface emission rate of the source. Both BeO Thin Film TSEE detectors and EICs were tested in tritium contaminated areas at the Oak Ridge National Laboratory (ORNL) and at the Savannah River Site (SRS). Problems encountered within these facilities severely affected contamination estimates made with TSEE and EIC detectors. At ORNL, tritium surface contamination estimates were as follows: TSEE -1,200 to 5,900,000 dpm/100 cm2; EIC - 37,000 to 197,000 dpm/100 cm2 At SRS, tritium surface contamination estimates were as follows: TSEE - 1,500 to 27,000 dpm/100 cm2; EIC - 50,000 to 360,000 dpm/100 cm2.

Degree
Master of Science
Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

Thesis95B76.pdf

Size

4.21 MB

Format

Unknown

Checksum (MD5)

7da4cb4ba2beb07d5e15d55bab772d3d


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science