Solar dryer performance during hay drying cycle

Date Issued
August 1, 1993
Author(s)
Bales, Barton McAmis
Advisor(s)
Bobby L. Bledsoe
Additional Advisor(s)
William E. Hart
Robert Freeland
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/43383
Abstract

Thermal efficiency was evaluated for the 32-bale, solar-heated, forced-air dryer for large round hay bales during 1992 at the Middle Tennessee Experiment Station near Spring HiU, Tennessee. The tests were conducted in accordance with the new ASAE Standard S-423 (1993), Thermal Performance Testing of Solar Air Heaters, except mass airflow rate was measured at the entrance to the collector instead of the exhaust. Day-long efficiencies for the 4-day test period in mid- September ranged from 49 to 52 percent which was lower than the design goal of 60 percent efficiency.


Airflow rate was measured in 2.4-m (8-ft) segments of the total entrance width of 19.5 m (64.5 ft). Each segment was 12.5 percent of the total entrance width. Airflow measurements taken over this reduced air entrance width decreased research costs without a significant reduction in measurement accuracy. Preliminary airflow rate measurements at four locations along the entrance width showed identical flow rates within 1 percent except at the extreme ends of the entrance where flow rates were 6 percent higher than at the central part of the entrance length. Volumetric airflow rate per unit area of collector surface was measured to be 0.067 m3sec/m2 (13.27 cfm/ft2) which was lower than the design goal of 0.076 m3sec/m2 (15.00 cfm/ft2).

The apparatus for measuring compensated air flow rates included a thin plate orifice and a variable speed fan. The fan accurately added back pressure energy lost by the airstream due to pressure drop through the orifice. Thus, "measured air was delivered to the collector entrance at atmospheric pressure (measured to be within 2.5 pascals (0.01 inches of water) of ambient air pressure). An experiment was designed to evaluate the effectiveness of a moisture extraction exhaust fan positioned in the fan room above control doors that sealed the collector exhaust chamber from the dryer fans. At morning start-up, the exhaust fan removed moisture condensation from the collector air ducts prior to dryer fan powerup. This procedure prevented moisture addition back to partially-dry bales before the relative humidity of the fan room air dropped to the desired upper limit of 60 percent.

Degree
Master of Science
Major
Biosystems Engineering Technology
File(s)
Thumbnail Image
Name

uc_id_1473gk0_Gi5oASKKVB0nckXXoDazLDhpB_export_download.pdf

Size

17.68 MB

Format

Adobe PDF

Checksum (MD5)

8af95220bbb75080a2c449ee8a0302ab


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science