The Development of a Parameterized Scatter Removal Algorithm for Nuclear Materials Identification System Imaging

Date Issued
May 1, 2010
Author(s)
Grogan, Brandon Robert
Advisor(s)
John Mihalczo
Additional Advisor(s)
Thomas Handler
Laurence Miller
Lawrence Townsend
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/28211
Abstract

This dissertation presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects non-intrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross-sections of features inside the object can be determined. The cross sections can then be used to identify the materials and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons which are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using the PSRA resulted in an improvement of the chi-squared test by a factor of 60 or more when applied to simple homogeneous objects.

Subjects

neutron radiography

scatter removal

MCNP modeling

MCNP-PoliMi

NMIS

Disciplines
Nuclear Engineering
Degree
Doctor of Philosophy
Major
Nuclear Engineering
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

PhD_Dissertation_Grogan_UTNE_Submit.pdf

Size

3.86 MB

Format

Adobe PDF

Checksum (MD5)

afe405254c524053dd8f6b8d5130b1eb

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify