Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Accident dosimetry using panasonic dosimeters
Details

Accident dosimetry using panasonic dosimeters

Date Issued
December 1, 1994
Author(s)
Lee, Eugenia Beth
Advisor(s)
Laurence F. Miller
Additional Advisor(s)
Peter Groer
Dave Simpson
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/32921
Abstract

Criticality accident personnel dosimetry involves the evaluation of high doses in mixed fields of gamma rays and neutrons. Those who work in areas where there is potential for a criticality accident or other extremely high neutron doses need dosimeters, such as thermoluminescent dosimeters, capable of measuring doses associated with these scenarios. In order for a dosimeter to be used in these areas, it must be characterized for accident or high level neutron dosimetry. Panasonic thermoluminescent dosimeters (TLDs), using lithium tetraborate, have been characterized for accident and high level neutron dosimetry.


The characterization of these dosimeters includes calculating the dosimeter's response to neutrons, determining the dosimeter's response to various possible accident scenarios, and evaluating TLD's response at high doses.

An accurate determination of neutron dose is complicated by the fact that dose per source neutron is a strong function of energy. Correction factors for dose and for the dosimeter's response are obtained for 115 different spectra, and these effects are incorporated into a single spectral correction factor (SCF) for each spectrum. These SCFs should be improved, however, to correct for neutrons scattered from the body. Also, a linear combination of element responses to bare, D2O-moderated, and polyethylene- moderated californium-252 and americium-241/beryllium are used to obtain some spectral information from any unknown spectrum.

Since accident dosimetry involves extremely high doses, the element responses have been tested for linearity from one to one thousand rad with D2O-moderated 252Cf. Corrections for element responses due to doses above ten rad have been determined.

Results from this study demonstrate that Panasonic dosimeters, using lithium tetraborate, can be used by personnel who work in areas where there is a possibility for a criticality accident.

Degree
Master of Science
Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

Thesis94L45.pdf

Size

3.8 MB

Format

Unknown

Checksum (MD5)

b1fea28aa653ece132a33aacbfa114b3

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify