Sources of Heat in Synthetic Turf Systems

Date Issued
August 1, 2015
Author(s)
Thoms, Adam William  
Advisor(s)
John C. Sorochan
Additional Advisor(s)
James T. Brosnan
Brandon J. Horvath
Dean A. Kopsell
Jaehoon Lee
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/24596
Abstract

With options for cooling synthetic turf limited, an outdoor experiment was conducted at the University of Tennessee Center for Athletic Field Safety (Knoxville, TN) to develop a model to predict maximum, minimum, and mean synthetic turf surface temperature using forecasted atmospheric conditions. Synthetic turf surface temperature varied due to both air temperature and solar radiation. Predictive models using these data accounted for 86, 95, and 94% of the variation in daily maximum, minimum, and mean synthetic turf surface temperature. Accuracy of these models for predicting daily mean and minimum synthetic turf surface temperature using 48 and 72-hour forecasted air temperature data was +/- 1 °C, while the daily maximum synthetic turf temperature (+/- 4.7 to 5.3 °C) was less accurate.


Infilled synthetic turf contains several components that may affect surface temperature including the aggregate base layer, crumb rubber and silica sand infill, synthetic turf backing, and polyethylene pile fibers themselves. In a glasshouse study at the University of Tennessee (Knoxville, TN) each component of an infilled synthetic turf system was placed in a controlled rise temperature chamber for 4 hours with surface temperature monitored. Surface temperatures for components containing pile fibers were 15 °C greater than those without fibers. No differences in temperature were observed among fibers with and without crumb rubber infill. These data indicate that fibers affect surface temperature on synthetic turf more than other components.

Research was also conducted at the University of Tennessee investigating methods for reducing surface temperature on infilled synthetic turf again in a controlled temperature rise chamber for 4 hours, including the use of reflective pigments, fans, and water absorbent pads placed below the turf surface. Results from this study indicate the greatest reduction in surface temperature (32 °C compared to the control) was the fan applying forced air to the surface. In addition, reflective pigments and sub-surface forced air applied through the aggregate base each offered lower surface temperatures than the non-treated control. Applications of forced air to the surface were further tested in a field study. In the field studies, the forced air significantly reduced surface temperature compared to non-treated controls.

Subjects

Artifical Turf

Temperature

Safety

Fibers

Disciplines
Other Plant Sciences
Degree
Doctor of Philosophy
Major
Plants, Soils, and Insects
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

Dissertation_Thoms_1.docx

Size

172.76 KB

Format

Microsoft Word XML

Checksum (MD5)

3dd8bc3298a459f20c6d2079c879c81d

Thumbnail Image
Name

Dissertation_Thoms_6.pdf

Size

460.87 KB

Format

Adobe PDF

Checksum (MD5)

d15cd90aeeaa9c455a3f07b776aac7c4


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science