Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. EVALUATION OF GEOMETRIC SCALE EFFECTS FOR SCRAMJET ISOLATORS
Details

EVALUATION OF GEOMETRIC SCALE EFFECTS FOR SCRAMJET ISOLATORS

Date Issued
August 1, 2010
Author(s)
Perez, Jaime Enrique  
Advisor(s)
Dr. Stephen Corda
Additional Advisor(s)
Peter U. Solies
Frank G. Collins
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/43791
Abstract

A numerical analysis was conducted to study the effects of geometrically scaling scramjet inlet-combustor isolators. Three-dimensional fully viscous numerical simulation of the flow inside constant area rectangular ducts, with a downstream back pressure condition, was analyzed using the SolidWorks Flow Simulation software. The baseline, or 1X, isolator configuration has a 1” x 2.67” cross section and 20” length. This baseline configuration was scaled up based on the 1X configuration mass flow to 10X and 100X configurations, with ten and one hundred times the mass flow rate, respectively. The isolator aspect ratio of 2.67 was held constant for all configurations. To provide for code validation, the Flow Simulation program was first used to analyze a converging-diverging channel and a wind tunnel nozzle. The channel case was compared with analytical theory and showed good agreement. The nozzle case was compared with AFRL experimental data and showed good agreement with the entrance and exit conditions (Pi0= 40 psia, Ti0= 530ºR, Pe= 18.86 psia, Te= 456ºR, respectively). While the boundary layer thickness remained constant, the boundary layer thickness with respect to the isolator height decreased as the scale increased. For all the isolator simulations, a shock train was expected to form inside the duct. However, the flow simulation failed to generate this flow pattern, due to improper sizing of the isolator and combustor for a 3-D model or having a low pressure ratio of 2.38. Instead, a single normal shock wave was established at the same relative location within the length of each duct, approximately 80% of the duct length from the isolator entrance. The shape of the shock changed as the scale increased from a normal shock wave, to a bifurcated shock wave, and to a normal shock train, respectively for the 1X, 10X, and 100X models.

Subjects

Scaling

Isolator

Scramjet

Hypersonic

Combustor

Inlet

CFD

Disciplines
Aerodynamics and Fluid Mechanics
Propulsion and Power
Degree
Master of Science
Major
Aviation Systems
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

Jaime_Final_UTK.doc

Size

11.72 MB

Format

Microsoft Word

Checksum (MD5)

115dc90a60e222a6f728e0ab6e5929ad

Thumbnail Image
Name

Perez_Jaime_August2010thesis.pdf

Size

1.48 MB

Format

Adobe PDF

Checksum (MD5)

69f6c17cdc12fa70cad4a2ccbc04e40e

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify