  5. Study of a Position Sensing Gas Proportional Detector for Decommissioning
Details

Study of a Position Sensing Gas Proportional Detector for Decommissioning

Date Issued
May 15, 2020
Author(s)
Echterling, Christopher
Advisor(s)
Jason Hayward
Additional Advisor(s)
Lawrence Heilbronn
Eric Lukosi
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/41855
Abstract

Decontamination and decommissioning as required by the Nuclear Regulatory Commission is guided by the Multi-Agency Site Survey and Investigation Manual. This manual lays out the types of radiological surveys required for decommissioning and the methods and equations to analyze the data. By optimizing detectors based on this manual, a business engaged in providing decommissioning services can become more competitive.To optimize a detector for decommissioning, position-sensing gas proportional detectors were investigated to determine critical design criteria. Gas proportional detectors are already commonly in use for decommissioning work. By adding position sensing, additional speed and efficiency of surveying can be gained.Position-sensitive gas proportional designs appropriate for the application of interest were reviewed. Some of the critical design parameters for the anode include the diameter, the resistance, the capacitance, and the tension that can be applied to the anode. The counting gas and pressure and applied bias voltage are required to calculate the gas amplification. A prototype detector was constructed using a resistive anode with the intent to use charge division to sense position and these design criteria were investigated more fully. A one meter long by 10 centimeter wide detector with five resistive anodes in a planar configuration was constructed. Anode capacitance must be carefully controlled to ensure that the anode tension is sufficiently high to prevent detector sparking at voltages large enough to ensure gas amplification is on the order of 102. The intrinsic noise of the detector is problematic and requires careful preamplifier design and specification. The preamplifiers should be designed in conjunction with the detector to ensure optimal functionality.

Degree
Master of Science
Major
Nuclear Engineering
File(s)
Thumbnail Image
Name

utkirtd_12895.pdf

Size

1.62 MB

Format

Adobe PDF

Checksum (MD5)

5bc077614f3f388c50870908c0f150bc

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify