The effects of noise reduction technologies on the acceptance of background noise

Date Issued
May 15, 2009
Author(s)
Lowery, Kristy Jones
Advisor(s)
Patrick N. Plyler
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/27326
Abstract

The effect of noise reduction technologies in hearing aids on a listener's acceptable noise level (ANL) was investigated. Technology designed to reduce noise within hearing aids; directional microphones (D-Mic), digital noise reduction algorithms (DNR) and the combination of the two technologies (Combo) were employed in the presence of three distinctly different background noises (single talker speech, speech shaped noise, and multi-talker babble). The same pair of twelve channel wide dynamic range compression behind-the-ear hearing instruments was fit on each of thirty participants. The hearing aids were set with four memories: no noise reduction technology activated (baseline), only D-Mic activated, only DNR activated, and the Combo of technologies activated. All other hearing aid settings and features remained the same across memories. Acceptable noise levels were investigated in each memory in the presence of each noise.In addition, subjective preference rankings of the noise reduction technology were obtained within each background noise (1= best, 3=worst). Listeners yielded significantly lower (better) ANL scores with Combo relative to D-Mic and DNR; and scores obtained with D-Mic were significantly better than those obtained with DNR. A technology x noise interaction was observed only for speech shaped noise in DNR, with listeners accepting significantly more noise in the presence of speech shaped noise than background noise containing speech. Listeners preferred D-Mic and Combo programs significantly more than DNR in the presence of single talker and multi-talker babble, and preferred Combo significantly more in the presence of speech shaped noise. Overall, listeners preferred the D-Mic and Combo programs equally as much and significantly more than DNR.In reviewing the preference data along with the ANL data, it is evident that improving an ANL with hearing aid technology is noticeable to listeners, at least when examined in this laboratory setting. These results indicate that listeners prefer noise technologies that improve their ability to accept noise.

Subjects

Speech and hearing sc...

Degree
Doctor of Philosophy
Major
Speech and Hearing Science
File(s)
Thumbnail Image
Name

LoweryKristyJones.pdf

Size

222 KB

Format

Adobe PDF

Checksum (MD5)

7f9b326dc3141616095889e3aa99e100

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify