The diagnostic tool for air sensor functions

Date Issued
August 1, 1993
Author(s)
Liu, Bin
Advisor(s)
Paul B. Crilly
Additional Advisor(s)
Koch
Waller
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/33308
Abstract

In this thesis project, a hand-held, microprocessor-based, battery operated instrument to accurately evaluate an air sensor switch has been designed, built and tested. The key component is a Motorola M68HC711, 8-bit microprocessor.


The prototype of the diagnostic tool for the air sensor has been evaluated both at a laboratory of the University of Tennessee, Knoxville and at a check processing machine at a bank operating center. The preliminary results measured in both the simplified simulation device and a real custom check processor are satisfactory.

Degree
Master of Science
Major
Environmental Engineering
File(s)
Thumbnail Image
Name

Thesis93L584.pdf

Size

3.29 MB

Format

Unknown

Checksum (MD5)

782e8d1a31abf99c33b04472740405a7


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science