Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Doctoral Dissertations
  5. Beta decay of neutron-rich isotopes of zinc and gallium
Details

Beta decay of neutron-rich isotopes of zinc and gallium

Date Issued
May 1, 2015
Author(s)
Al-Shudifat, Mohammad Faleh M.  
Advisor(s)
Robert Grzywacz
Additional Advisor(s)
Soren Sorensen
Thomas Papenbrock
Jason P. Hayward
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/24388
Abstract

Beta-decays of neutron-rich nuclei near the doubly magic 78Ni [78Ni] were studied at the Holifield Radioactive Ion Beam Facility. The half-life and the gamma-gamma coincidence spectra were used to study the nuclear structure. A new 82,83Zn [82Zn, 83Zn] decay-scheme was built, where a 71±7% beta-delayed neutron branching ratio was assigned in 82Zn [82Zn] decay. New gamma-ray lines and energy levels observed in 82,83Ga [82Ga, 83Ga] beta-decay were used to update previously reported decay-schemes. The experimental results were compared to shell model calculations, which postulate the existence of Gamow-Teller transitions in these decays. The half-lives of 155±17 and 122±28~ms were determined for 82,83Zn, respectively.


In order to enable future studies of very neutron rich isotopes a new detector was developed as a second project. This detector is intended for use in fragmentation type experiments, which require segmentation in order to enable implantation-decay correlations. In addition, the detector requires good timing resolution for neutron time-of-flight experiments. A Position Sensitive Photo-Multiplier Tube (PSPMT) from Hamamatsu coupled with a 16x16 fast pixelated plastic scintillator was used. The PSPMT's anodes form 8x8 segment panel used for position reconstruction. Position localization has been achieved for energies range of 0.5-5 MeV. A single signal dynode (DY12) shows a sufficient time resolution between this signal and the anode's signals, which enable us to used DY12 signal alone as a trigger for timing purposes. The detector's DY12 signals was tested with reference detectors and it provided a sub-nanosecond time resolution through the use of a pulse-shape analysis algorithm, which is sufficient for use in experiments with the requirement for the fast timing. The detector ability to survive after implanting high-energy ions was tested using a laser that simulated energy of 1 GeV. The recovery time of the detector in this situation was 200 nanosecond.

Subjects

Beta-decay

Zinc

Gallium

NuShellX

Gamow-Teller

PSPMT

Disciplines
Nuclear
Physics
Degree
Doctor of Philosophy
Major
Physics
Embargo Date
May 15, 2016
File(s)
Thumbnail Image
Name

my_dissertation.pdf

Size

8.31 MB

Format

Adobe PDF

Checksum (MD5)

2478352c884d62d9c749fe3060c21d68


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science