Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation

Date Issued
December 1, 2015
Author(s)
Yang, Liu  
Advisor(s)
Leon M. Tolbert
Additional Advisor(s)
Fred Wang
Kevin Tomsovic
Judy Day
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/24758
Abstract

To bridge the gap between power system research and their real application in power grids, a Hardware Test-Bed (HTB) with modular three-phase power converters has been developed at the CURENT center, the University of Tennessee, Knoxville, to emulate transmission level power systems with actual power flowing.


This dissertation focuses on the development and verification of a real-time synchronous generator (SG) emulator in the HTB. The research involved in this dissertation aims at designing a proper control to achieve emulator performance goal and investigating the sources of error and its influence on interconnected SG-emulator networks.

First, different interface algorithms (IAs) are compared and the voltage type ideal transformer model (ITM) is selected considering the accuracy and stability. At the same time, closed-loop voltage control with current feed-forward is proposed to decrease the error caused by the non-ideality of the power amplifier.

The emulation is then verified through two different ways. First, the output waveforms of the emulator in experiment are compared with the simulation under the same condition. Second, a transfer function perturbation (TFP) based error model is obtained and redefined as the relative error for the amplitude and phase between the emulated and the target system over the frequency range of interest. The major cause of the error is investigated through a quantitative analysis of the error with varying parameters.

Third, the stability issue associated with the interconnection of two SG emulators is studied. The small signal models of the two-generation system with constant current and constant impedance load are developed, and the main reasons that cause instability are researched and verified. The developed SG emulator is also verified in the two-area system by comparing the system dynamics visually.

At last, the 6th-order SG model including transformer voltages and saturation effect is applied in the three-phase symmetrical fault scenario. Control parameters are designed based on the TFP error evaluation of the fault condition. The developed SG emulator is then tested and verified in line-to-line fault condition. In addition, the stability of the new SG emulator is studied again and compared with the previous emulation.

Subjects

Three-phase converter...

Synchronous generator...

power hardware-in-the...

real time

stability

microgrid

Disciplines
Power and Energy
Degree
Doctor of Philosophy
Major
Electrical Engineering
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

Full_Dissertation_150816.pdf

Size

3.89 MB

Format

Adobe PDF

Checksum (MD5)

3096d68bf852609d289eb3d958cb54ec

Thumbnail Image
Name

Proposal_Liu_Yang.docx

Size

14.13 MB

Format

Microsoft Word XML

Checksum (MD5)

d1823baf7686792afc7215cbc2442024


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science