Development of a microcomputer based flowmeter for liquid volume flow in partially full pipes

Date Issued
June 1, 1980
Author(s)
Barker, Leland Wayne
Advisor(s)
Donald W. Bouldin
Additional Advisor(s)
R E Bodenheimer
R W Rochelle
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/37104
Abstract
A flowmeter was designed, developed and constructed to measure total volume flow in partially full pipes because a reliable, accurate flowmeter was not commercially available. The flowmeter system uses a pitot tube type sensor with a differential pressure transmitter and a bubbler tube with a differential pressure transmitter to obtain flow velocity and liquid level information. A microcomputer performs all the flow calculations from this information. The completed system exceeds all desired performance specifications for reliability, accuracy, response time and flexibility.
Degree
Master of Science
Major
Electrical Engineering
File(s)
Thumbnail Image
Name

Thesis80B374.pdf

Size

2.17 MB

Format

Unknown

Checksum (MD5)

5fc725b2ee4c9228a04d4d359d035001


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science