Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. Design and comparison of a small, monolithic weighing lysimeter to a large lysimeter and to the penman and penman-monteith equations
Details

Design and comparison of a small, monolithic weighing lysimeter to a large lysimeter and to the penman and penman-monteith equations

Date Issued
May 1, 1998
Author(s)
Wheeler, Christopher Ray
Advisor(s)
Ronald E. Yoder
Additional Advisor(s)
John B. Wilkerson
Raj Raman
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/31617
Abstract

The design, construction, installation, and evaluation of a small, monolithic, weighing lysimeter (<1 m2) is described. The small lysimeter is composed of three components: an outer container, a soil column assembly (soil container and soil column), and a weighing mechanism. The circular lysimeter has a surface area of 0.072 m2 and an undisturbed column depth of 0.61 m constructed using 12” PVC (polyvinyl chloride) pipe. The weighing device is comprised of an aluminum frame and an electronic load cell that only weighs the “live load” or change in water content of the lysimeter. This is made possible by counterweighting the “dead load” or dry soil and container. It was designed to be easily installed in a single circular pit by two or three persons, with minimal disturbance to the surrounding soil and crop. The weighing device was constructed and tested in an environmentally controlled chamber for temperature effects and sensitivity. After concluding that the temperature effects were negligible and the sensitivity was sufficient, the soul column assembly was constructed and the lysimeter was installed in the field. It was installed at the Plateau Experiment Station in Crossville, TN near an existing large weighted lysimeter (4 m2) and a weather station. The lysimeter was operated for 90 days and the ET measurements were compared to ET measurements from the existing large lysimeter and ET values calculated from on-site weather data using two ET estimation equations. This field test revealed that the small lysimeter stayed within 1.5 mm of the large lysimeter and had an accuracy of 0.680 mm when the lysimeter soil area. The small lysimeter ET measurements almost always exceed the large lysimeter. This difference could not be strongly correlated to any of the weather parameters. When using the total lysimeter area, the small lysimeter had an accuracy if 0.290 mm, which was very similar to the accuracy of the two estimation equations (0.342 mm and 0.272 mm). The results indicate that by using the lysimeter soil area, the small lysimeter did not meet the specified accuracy. However, using the total lysimeter area, the small lysimeter could accurately measure ET in a humid climate.

Degree
Master of Science
Major
Biosystems Engineering Technology
File(s)
Thumbnail Image
Name

Thesis98W49.pdf

Size

5.77 MB

Format

Unknown

Checksum (MD5)

eba51199fe55c82943992b52dfca55f0


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science