Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Graduate School
  4. Masters Theses
  5. A LOW-POWER APPROACH FOR FRONT END BIOLOGICAL SIGNAL CONDITIONING
Details

A LOW-POWER APPROACH FOR FRONT END BIOLOGICAL SIGNAL CONDITIONING

Date Issued
December 1, 2014
Author(s)
Taylor, Logan Smith  
Advisor(s)
Syed K. Islam
Additional Advisor(s)
Benjamin J. Blalock
Charles Britton
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/39205
Abstract

In a lab-on-a-chip (LOC) application, the measurement of small analog signals such as local temperature variation often involves detection of very low-level signals in a noisy micro-scale environment. This is true for other biomedical monitoring systems as well. These systems observe various physiological parameters or electrochemical reactions that need to be tracked electrically. For temperature measurement pyroelectric transducers represent an efficient solution in terms of speed, sensitivity, and scale of integration, especially when prompt and accurate temperature monitoring is desired.


The ability to perform laboratory operations on a small scale using miniaturized LOC devices is a promising biosensing technique. The advantages of using LOC include faster time of analysis, low reagent costs, and reduced amount of chemical wastes. The application of portable, easy-to-use, and highly sensitive LOC biosensors for real-time detection could offer significant advantages over the currently used analytical methods.

This thesis presents design and analysis of a low frequency charge amplifier suited for biological sample applications, with a wide window for signal size and speed. The charge amp has been fabricated in a commercial 180nm CMOS process. The circuit has been tested for signals in 100Hz-100kHz range with a max charge of 250nC.

This thesis begins with a study of the transducer that produces the charge for the charge amplifier. Next it moves into the design of low power charge sensitive amplifiers, along with an analysis of various components essential to the makeup of the design. The charge amplifier circuit is simulated using analytical model as well as numerical simulation tools. Finally, the test setup is presented and the measurement results are compared with those obtained from simulation.

Subjects

Front End

Charge Amp

CMOS

Pseudo Resistor

PreAmplifer

BioSignal

Disciplines
Biomedical
Biomedical Devices and Instrumentation
Electronic Devices and Semiconductor Manufacturing
VLSI and Circuits, Embedded and Hardware Systems
Degree
Master of Science
Major
Electrical Engineering
Embargo Date
January 1, 2011
File(s)
Thumbnail Image
Name

Logan_Thesis_111314.docx

Size

11.92 MB

Format

Microsoft Word XML

Checksum (MD5)

c45fe5e2c2a2c1dc301838b8d62e1abf

Thumbnail Image
Name

Logan_Thesis_Final.pdf

Size

2.2 MB

Format

Adobe PDF

Checksum (MD5)

551cd413830e98fd345591acd387918a


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science