Distribution Congestion Management Using CVSR Devices

Date Issued
August 1, 2023
Author(s)
Ciftci, Okan  
Advisor(s)
Kevin Tomsovic
Additional Advisor(s)
Kevin Tomsovic
Fangxing Li
Seddik M. Djouadi
Mingzhou Jin
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/19508
Abstract

Power demand and supply must be in balance to maintain frequency and stable power flow in distribution and transmission networks. Power flow control is an important problem where flows must be held within equipment limits. Distribution systems may experience congestion during peak consumption hours. Such congestion can overload distribution lines and transformers, particularly, in dense urban areas. Similar to the power electronic devices in the transmission network, power flow control devices are available for the distribution systems. However, there are very few control units in the distribution systems. D-STATCOM, energy storage, phase-shifting transformers, distributed generation (DG) and switches can be used to control power flow in the distribution systems.


The continuously variable series reactor (CVSR) is a newly proposed device and is used in this study for its ability to control distribution power flow. Compared to other power flow control equipment, the CVSR device is a reliable, fast-acting unit, and most importantly, economically low cost. The CVSR can be used to regulate the reactance on the primary side of a transformer to control power distribution among transformers in order to relieve overloading in a meshed distribution grid. This approach can allow a distribution system to avoid or defer transformer upgrades. An optimization problem is formulated to identify location and settings to relieve overloads. To integrate and model the CVSR device in the distribution network, a method is developed and simulation is performed using MATLAB and OpenDSS. The results are verified with the benchmark results on OpenDSS software. As a result, a few ohm reactance CVSR is shown to be adequate to relieve loading on the transformers in a practical system. In addition, it was found that a piecewise approximation works well for mitigating the overloads and optimal CVSR locations on realistic meshed networks. The IEEE 342-node low voltage networked test system (LVNTS) and a portion of the Consolidated Edison's partial meshed distribution system are used to evaluate performance. Future work includes optimal location of CVSR devices with consideration of dynamic conditions, integration of advanced optimization techniques, expansion to other test systems and identification of open-mains in the meshed grids.

Subjects

optimization

power flow

variable series react...

distribution system

congestion management...

Disciplines
Electrical and Electronics
Power and Energy
Degree
Doctor of Philosophy
Major
Electrical Engineering
Embargo Date
August 15, 2026
File(s)
Thumbnail Image
Name

Okan_Ciftci_Dissertation_Second_Submission.pdf

Size

7.45 MB

Format

Adobe PDF

Checksum (MD5)

07bbaf442b1c356fdf1f5706938cc455


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science