Repository logo
Log In(current)
  1. Home
  2. Colleges & Schools
  3. Tickle College of Engineering
  4. Engineering -- Other Materials (Newsletters, Reports, Etc.)
  5. Nuclear Engineering Reports
  6. Characterization of Heavy Ion Beams at the Heavy Ion Medical Accelerator in Chiba Using a Li-drifted 5-mm Silicon Detector
Details

Characterization of Heavy Ion Beams at the Heavy Ion Medical Accelerator in Chiba Using a Li-drifted 5-mm Silicon Detector

Date Issued
October 1, 2012
December 1, 2012
Author(s)
Lang, Alexander
Advisor(s)
Lawrence Heilbronn
Additional Advisor(s)
Lawrence Townsend
Jason Hayward
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/52111
Abstract

Measurements were taken at the Heavy Ion Medical Accelerator in Chiba, Japan (HIMAC) to characterize accelerator beams to assist in the study of various tissue equivalent proportional counters (TEPCs) designed by Colorado State University (CSU), Oklahoma State University (OSU), and the National Aeronautics and Space Administration (NASA). There were four beams that were part of the HIMAC experiment:

  • 290 MeV/nucleon carbon
  • 150 MeV/nucleon helium
  • 500 MeV/nucleon argon
  • 500 MeV/nucleon iron


For the first time ever, a single, 5-mm lithium drifted silicon detector was used to characterize the beam and measure the spectrum of particles striking the TEPCs. If successful, this new methodology can greatly simplify previously used methods and reduce the amount of beam time needed to characterize the beam. Data from the detector was used to yield information on the particle’s species (atomic number) and energy. The data analysis was more complex than the standard analysis performed on Si-detector data due to several complications that became evident during the experiments. The 5mm Silicon detector used to analyze the beams was discovered to have suffered radiation damage from previous experiments. On the night of the Helium run, there was limited time to perform the TEPC measurements, so silicon detector measurements of the beam were not taken. The data for the Argon beam was corrupted, and all information that was taken was lost. In spite of these difficulties, useful data was extracted from the carbon and iron runs.

Subjects

Beam characterization...

silicon detectors

heavy ion accelerator...

Disciplines
Nuclear
Embargo Date
March 23, 2018
File(s)
Thumbnail Image
Name

Characterization_of_Heavy_Ion_Beams_at_the_Heavy_Ion_Medical_Accelerator_in_Chiba_using_a_Li_drifted_5_mm_Silicon_Detector.pdf

Size

2 MB

Format

Adobe PDF

Checksum (MD5)

b0f561fd89ad62a34ac38f71187a2d32


University Libraries

1015 Volunteer Boulevard
Knoxville, TN 37996
865-974-4351

Map & Directions
Donate to the Libraries
  • About
  • John C. Hodges Society
  • Speaking Volumes magazine
  • Outreach
  • Directory
  • Employment
  • Policies
  • Library Intranet
University of Tennessee power T logo

The University of Tennessee, Knoxville
Knoxville, Tennessee 37996
865-974-1000

Events
A-Z
Apply
Privacy
Map
Directory
Give to UT
Accessibility

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science