Dynamic Response Analysis of the Human Knee Joint

Date Issued
May 1, 2005
Author(s)
Bohleber, Brandi L
Advisor(s)
Mehran Kasra
Additional Advisor(s)
Richard Jendrucko
Jack Wasserman
Permanent URI
https://trace.tennessee.edu/handle/20.500.14382/42196
Abstract

Objective. To perform frequency response analysis of passive intact and rneniscectomized human knee joints under body mass. The knee dynamic system parameters and their alterations with different preloads and displacement amplitudes will be determined.


Design. Using an Instron Mechanical Testing System, specially designed fixtures, and the following softwares: WaveMaker, Excel, LabView, and Matlab, the knees were dynamically tested and analyzed.

Background. Studies have been performed to analyze the dynamic behavior of the human knee. However, no experimental study has investigated the dynamic response of the knee joint under an axial compressive dynamic loading condition considering the effect of the upper body mass.

Methods. Ten human knee joints were each placed in fixtures and secured in the Instron equipment, with an added mass to simulate body weight. The dynamic testing sequence consisted of creep tests, a series of frequency sweeps at increasing amplitudes, and relaxation tests. This testing series was performed with the knee in full extension, and at a 25-degree flexion angle. A meniscectomy was performed on each specimen, and the testing trial was performed again. The data from testing was then analyzed, and the joint response was obtained.

Results. The results indicated that the resonance frequency is significantly affected by change in preload and flexion angle. Increase in preload resulted with an increase in resonant frequency, but flexing the knee resulted in a decreased resonant frequency. The stiffness also decreased significantly when the knee was flexed. The joint compliance response increased up to two fold at resonant frequency compared with that of 1 Hz frequency at different joint conditions.

Conclusion. The compliance graphs had similar shapes and had interesting trends that yielded results that can be used as reference data for future studies and rehabilitation means. The analysis indicated that there is a range in the dynamic factors depending on the testing conditions. The meniscectomy had a significant effect on the joint response as well.

Disciplines
Engineering Science and Materials
Degree
Master of Science
Major
Engineering Science
Embargo Date
December 1, 2011
File(s)
Thumbnail Image
Name

BohleberBrandi.pdf

Size

16.46 MB

Format

Adobe PDF

Checksum (MD5)

5d458b08836e1339787e26bd3648b2d5

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Contact
  • Libraries at University of Tennessee, Knoxville
Repository logo COAR Notify